{"id":84032,"date":"2023-06-06T14:58:29","date_gmt":"2023-06-06T14:58:29","guid":{"rendered":"https:\/\/www.controltecnica.com\/?p=84032"},"modified":"2025-02-05T18:53:14","modified_gmt":"2025-02-05T18:53:14","slug":"uso-de-nanodrop-one-para-cuantificacion-de-clorofilas","status":"publish","type":"post","link":"https:\/\/www.controltecnica.com\/pt\/uso-de-nanodrop-one-para-cuantificacion-de-clorofilas\/","title":{"rendered":"Uso de Nanodrop One para cuantificaci\u00f3n de clorofilas"},"content":{"rendered":"<h3><strong>Cuantificaci\u00f3n de Clorofila Usando NanoDrop One: Un M\u00e9todo Personalizado<\/strong><\/h3>\n<h3><strong><img decoding=\"async\" class=\"alignnone wp-image-84036\" src=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/Nanodrop-One-300x251.png\" alt=\"\" width=\"498\" height=\"417\" srcset=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/Nanodrop-One-300x251.png 300w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/Nanodrop-One-768x644.png 768w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/Nanodrop-One-14x12.png 14w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/Nanodrop-One-350x293.png 350w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/Nanodrop-One.png 940w\" sizes=\"(max-width: 498px) 100vw, 498px\" \/><\/strong><\/h3>\n<h3><strong>Introducci\u00f3n<\/strong><\/h3>\n<p>La cuantificaci\u00f3n de clorofila es crucial en diversos campos como la biolog\u00eda vegetal, las ciencias ambientales y la ecotoxicolog\u00eda. Utilizando el espectrofot\u00f3metro de microvol\u00famenes NanoDrop One de Thermo Scientific, es posible medir con precisi\u00f3n las clorofilas a y b, esenciales para la fotos\u00edntesis en plantas y algas.<\/p>\n<h3><strong>\u00bfQu\u00e9 es la Clorofila?<\/strong><\/h3>\n<p>La clorofila a convierte la energ\u00eda de la luz en energ\u00eda qu\u00edmica y se encuentra en todas las plantas y algas verdes. La clorofila b, un pigmento accesorio, transfiere la luz absorbida a la clorofila a.<\/p>\n<h3><strong><img decoding=\"async\" class=\"alignnone wp-image-84037\" src=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-300x158.png\" alt=\"\" width=\"653\" height=\"344\" srcset=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-300x158.png 300w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-1024x538.png 1024w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-768x403.png 768w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-18x9.png 18w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-350x184.png 350w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila.png 1200w\" sizes=\"(max-width: 653px) 100vw, 653px\" \/><\/strong><\/h3>\n<h3><strong>M\u00e9todo de Cuantificaci\u00f3n<\/strong><\/h3>\n<p>Para cuantificar la clorofila, se utiliza la espectrofotometr\u00eda, que mide la absorbancia de la luz. La clorofila a tiene picos de absorbancia a 433 nm y 666 nm, mientras que la clorofila b los tiene a 462 nm y 650 nm.<\/p>\n<h3><strong>Extracci\u00f3n y Preparaci\u00f3n<\/strong><\/h3>\n<p>Se pueden usar varios solventes para extraer la clorofila, como dimetilsulf\u00f3xido (DMSO), metanol y acetona acuosa. En este caso, se disuelven las clorofilas en DMSO y se realizan diluciones seriadas para su medici\u00f3n.<\/p>\n<h3><strong>Proceso Personalizado con NanoDrop One<\/strong><\/h3>\n<p>El software de NanoDrop One permite crear m\u00e9todos personalizados. Se definieron par\u00e1metros espec\u00edficos y f\u00f3rmulas para calcular y reportar los resultados de absorbancia y concentraci\u00f3n de clorofila.<\/p>\n<h3><strong><img decoding=\"async\" class=\"alignnone wp-image-84039\" src=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2-300x158.png\" alt=\"\" width=\"647\" height=\"341\" srcset=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2-300x158.png 300w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2-1024x538.png 1024w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2-768x403.png 768w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2-18x9.png 18w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2-350x184.png 350w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2024\/06\/clorofila-2.png 1200w\" sizes=\"(max-width: 647px) 100vw, 647px\" \/><\/strong><\/h3>\n<h3><strong>Resultados y Conclusi\u00f3n<\/strong><\/h3>\n<p>Los resultados mostraron una alta reproducibilidad y precisi\u00f3n en las mediciones, validando el uso del NanoDrop One para estos an\u00e1lisis. La baja desviaci\u00f3n est\u00e1ndar indica que este m\u00e9todo es fiable para la investigaci\u00f3n cient\u00edfica.<\/p>\n<h3><strong>Aplicaci\u00f3n y Beneficios<\/strong><\/h3>\n<p>Este m\u00e9todo proporciona una herramienta valiosa para los cient\u00edficos, permitiendo mediciones precisas y repetibles de clorofila, esenciales para avanzar en estudios medioambientales y biol\u00f3gicos.<\/p>","protected":false},"excerpt":{"rendered":"<p>Cuantificaci\u00f3n de Clorofila Usando NanoDrop One: Un M\u00e9todo Personalizado Introducci\u00f3n La cuantificaci\u00f3n de clorofila es crucial en diversos campos como [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":84037,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"iawp_total_views":25,"footnotes":""},"categories":[101],"tags":[],"class_list":["post-84032","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-instrumentacion-cientifica-bio"],"_links":{"self":[{"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/posts\/84032","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/comments?post=84032"}],"version-history":[{"count":3,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/posts\/84032\/revisions"}],"predecessor-version":[{"id":84265,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/posts\/84032\/revisions\/84265"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/media\/84037"}],"wp:attachment":[{"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/media?parent=84032"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/categories?post=84032"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.controltecnica.com\/pt\/wp-json\/wp\/v2\/tags?post=84032"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}