{"id":156847,"date":"2026-03-02T10:47:40","date_gmt":"2026-03-02T10:47:40","guid":{"rendered":"https:\/\/www.controltecnica.com\/?p=156847"},"modified":"2026-03-02T10:47:40","modified_gmt":"2026-03-02T10:47:40","slug":"errores-comunes-en-el-uso-de-las-centrifugas-de-laboratorio-y-como-evitarlos","status":"publish","type":"post","link":"https:\/\/www.controltecnica.com\/en\/errores-comunes-en-el-uso-de-las-centrifugas-de-laboratorio-y-como-evitarlos\/","title":{"rendered":"Errores comunes en el uso de las centr\u00edfugas de laboratorio y c\u00f3mo evitarlos"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div data-parent=\"true\" class=\"vc_row row-container\" id=\"row-unique-0\"><div class=\"row limit-width row-parent\"><div class=\"wpb_row row-inner\"><div class=\"wpb_column pos-top pos-center align_left column_parent col-lg-12 single-internal-gutter\"><div class=\"uncol style-light\"  ><div class=\"uncoltable\"><div class=\"uncell no-block-padding\" ><div class=\"uncont\" ><div class=\"uncode_text_column\" ><p>Las centr\u00edfugas est\u00e1n en casi todos los laboratorios. Se usan a diario, forma parte de la rutina&#8230; y precisamente por eso son uno de los equipos donde m\u00e1s errores se cometen.<\/p>\n<p>Errores peque\u00f1os, muchas veces por prisa o por exceso de confianza, que pueden traducirse en:<\/p>\n<ul>\n<li>Resultados poco reproducibles<\/li>\n<li>Da\u00f1os en las muestras<\/li>\n<li>Aver\u00edas costosas<\/li>\n<li>Riesgos para la seguridad del personal<\/li>\n<\/ul>\n<p>En este art\u00edculo vamos a repasar los errores m\u00e1s frecuentes en el uso de las centr\u00edfugas de laboratorio y c\u00f3mo evitarlos, para que este equipo tan \u00abnormal\u00bb no se convierta en una fuente de problemas.<\/p>\n<\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>1. No equilibrar correctamente las muestras<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Es, sin duda, el error m\u00e1s habitual.<\/p>\n<p><strong>\u00bfQu\u00e9 suele pasar?<\/strong><\/p>\n<p>Se colocan los tubos \u00abm\u00e1s o menos iguales\u00bb o se compensa el peso \u00aba ojo\u00bb. Total, es solo una centrifugaci\u00f3n r\u00e1pida&#8230;<\/p>\n<p><strong>\u00bfPor qu\u00e9 es un problema?<\/strong><\/p>\n<ul>\n<li>Vibraciones excesivas<\/li>\n<li>Desgaste prematuro del rotor<\/li>\n<li>Da\u00f1os en el eje del motor<\/li>\n<li>Riesgo de rotura de tubos<\/li>\n<\/ul>\n<p><strong>\u00bfC\u00f3mo evitarlo?<\/strong><\/p>\n<ul>\n<li>Equilibra siempre en peso, no solo en volumen<\/li>\n<li>Usa tubos del mismo peso y fabricante<\/li>\n<li>Si falta una muestra, utiliza un tubo de equilibrado con agua o tamp\u00f3n. No dejes huecos vac\u00edos en los adaptadores.<\/li>\n<li>Revisa que los tubos est\u00e9n colocados de forma sim\u00e9trica.<\/li>\n<\/ul>\n<p><strong>Regla de oro<\/strong>:<\/p>\n<p>Si vibra, algo no est\u00e1 bien.<\/p>\n<p>\n<\/div><div class=\"uncode-single-media  text-left\"><div class=\"single-wrapper\" style=\"max-width: 100%;\"><div class=\"tmb tmb-light  tmb-media-first tmb-media-last tmb-content-overlay tmb-no-bg\"><div class=\"t-inside\"><div class=\"t-entry-visual\"><div class=\"t-entry-visual-tc\"><div class=\"uncode-single-media-wrapper\"><img decoding=\"async\" class=\"wp-image-156865\" src=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/rotor-falcon-416.jpg\" width=\"363\" height=\"334\" alt=\"\" srcset=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/rotor-falcon-416.jpg 363w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/rotor-falcon-416-300x276.jpg 300w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/rotor-falcon-416-13x12.jpg 13w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/rotor-falcon-416-350x322.jpg 350w\" sizes=\"(max-width: 363px) 100vw, 363px\" \/><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div><\/div><\/div><\/div><\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>2. Utilizar un rotor inadecuado para la aplicaci\u00f3n<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>No todos los rotores sirven para todo, aunque encajen.<\/p>\n<p><strong>Errores habituales<\/strong><\/p>\n<ul>\n<li>Usar un rotor de \u00e1ngulo fijo cuando se necesita sedimentaci\u00f3n suave<\/li>\n<li>Sobrecargar el rotor sin revisar sus l\u00edmites<\/li>\n<li>Montar rotores incompatibles con la velocidad seleccionada<\/li>\n<\/ul>\n<p><strong>Consecuencias<\/strong><\/p>\n<ul>\n<li>Resultados poco reproducibles<\/li>\n<li>Da\u00f1os estructurales en el rotor<\/li>\n<li>Riesgos de seguridad<\/li>\n<\/ul>\n<p><strong>Buenas pr\u00e1cticas<\/strong><\/p>\n<ul>\n<li>Consulta siempre las especificaciones del rotor<\/li>\n<li>Respeta la velocidad m\u00e1xima permitida<\/li>\n<li>Usa el tipo de rotor adecuado para cada protocolo<\/li>\n<li>Revisa peri\u00f3dicamente el estado del rotor (grietas, corrosi\u00f3n, desgaste juntas&#8230;)<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>3. Ignorar la temperatura en centrifugaciones sensibles<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>En muchas aplicaciones biol\u00f3gicas, la temperatura importa (y mucho)<\/p>\n<p><strong>El error<\/strong><\/p>\n<p>Centrifugar muestras sensibles a temperatura ambiente \u00abporque es m\u00e1s r\u00e1pido\u00bb o porque la centr\u00edfuga refrigerada est\u00e1 ocupada.<\/p>\n<p><strong>El problema<\/strong><\/p>\n<ul>\n<li>Degradaci\u00f3n de prote\u00ednas o \u00e1cidos nicleicos<\/li>\n<li>Activaci\u00f3n enzim\u00e1tica no deseada<\/li>\n<li>Resultados inconsistentes entre ensayos<\/li>\n<\/ul>\n<p><strong>La soluci\u00f3n<\/strong><\/p>\n<ul>\n<li>Usa centr\u00edfugas refrigeradas cuando el protocolo lo requiera, o las muestras sean sensibles a m\u00e1s de 25\u00baC<\/li>\n<li>Preenfr\u00eda la c\u00e1mara con el rotor vac\u00edo si es necesario<\/li>\n<li>No asumas que \u00abunos minutos no afectan\u00bb. La temperatura puede aumentar a los 37-40\u00baC r\u00e1pidamente<\/li>\n<\/ul>\n<p>La reproducibilidad empieza por controlar todas las variables, tambi\u00e9n la temperatura.<\/p>\n<\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>4. No cerrar correctamente la tapa o forzar el cierre<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Puede parecer obvio, pero ocurre m\u00e1s de lo que te imaginas.<\/p>\n<p><strong>Qu\u00e9 suele pasar<\/strong><\/p>\n<ul>\n<li>Se fuerza el cierre cuando la tapa es motorizada, en lugar de un cierre acompa\u00f1ado suave<\/li>\n<li>No se comprueba el bloqueo de seguridad<\/li>\n<li>Se manipula la tapa antes de que el rotor se detenga por completo<\/li>\n<\/ul>\n<p><strong>Riesgos<\/strong><\/p>\n<ul>\n<li>Paradas de emergencia<\/li>\n<li>Da\u00f1os en el sistema de cierre de la tapa<\/li>\n<li>Riesgo para el operador<\/li>\n<\/ul>\n<p><strong>Recomendaciones<\/strong><\/p>\n<ul>\n<li>Comprueba siempre que los tubos est\u00e1n bien asentados<\/li>\n<li>No fuerces nunca el cierre<\/li>\n<li>Respeta los sistemas de seguridad del equipo<\/li>\n<\/ul>\n<p>La reproducibilidad empieza por controlar todas las variables, tambi\u00e9n la temperatura.<\/p>\n<\/div><div class=\"uncode-single-media  text-left\"><div class=\"single-wrapper\" style=\"max-width: 100%;\"><div class=\"tmb tmb-light  tmb-media-first tmb-media-last tmb-content-overlay tmb-no-bg\"><div class=\"t-inside\"><div class=\"t-entry-visual\"><div class=\"t-entry-visual-tc\"><div class=\"uncode-single-media-wrapper\"><img decoding=\"async\" class=\"wp-image-156863\" src=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/Gyrozen_1248R_New_Pic_6-6-23-NM.png\" width=\"551\" height=\"515\" alt=\"\" srcset=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/Gyrozen_1248R_New_Pic_6-6-23-NM.png 551w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/Gyrozen_1248R_New_Pic_6-6-23-NM-300x280.png 300w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/Gyrozen_1248R_New_Pic_6-6-23-NM-13x12.png 13w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/Gyrozen_1248R_New_Pic_6-6-23-NM-350x327.png 350w\" sizes=\"(max-width: 551px) 100vw, 551px\" \/><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div><\/div><\/div><\/div><\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>5. Falta de limpieza\u00a0 y mantenimiento b\u00e1sico<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>Las centr\u00edfugas tambi\u00e9n necesitan cuidados, aunque \u00abno lo parezca\u00bb.<\/p>\n<p><strong>Errores comunes<\/strong><\/p>\n<ul>\n<li>No limpiar derrames inmediatamente<\/li>\n<li>Dejar restos de sales o reactivos corrosivos<\/li>\n<li>No revisar juntas, adaptadores o cubetas<\/li>\n<\/ul>\n<p><strong>Consecuencias<\/strong><\/p>\n<ul>\n<li>Corrosi\u00f3n del rotor o de las juntas que lo tapan<\/li>\n<li>Olores, contaminaci\u00f3n cruzada<\/li>\n<li>Aver\u00edas evitables<\/li>\n<\/ul>\n<p><strong>Buenas pr\u00e1cticas<\/strong><\/p>\n<ul>\n<li>Limpia el rotor y la c\u00e1mara tras cualquier derrame<\/li>\n<li>Usa productos recomendados por el fabricante<\/li>\n<li>Programa revisiones peri\u00f3dicas<\/li>\n<li>Ap\u00f3yate en un servicio t\u00e9cnico especializado<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>6. Desconocer los l\u00edmites reales del equipo<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>No todas las centr\u00edfugas sirven para todo<\/p>\n<p><strong>El error<\/strong><\/p>\n<p>Forzar el eqipo m\u00e1s all\u00e1 de su dise\u00f1o:<\/p>\n<ul>\n<li>Velocidades excesivas<\/li>\n<li>Tubos no compatibles<\/li>\n<li>Cargas superiores a las recomendadas<\/li>\n<\/ul>\n<p><strong>El resultado<\/strong><\/p>\n<ul>\n<li>Reducci\u00f3n dr\u00e1stica de la vida \u00fatil<\/li>\n<li>Paradas inesperadas<\/li>\n<li>Costes de reparaci\u00f3n elevados<\/li>\n<\/ul>\n<p><strong>La clave<\/strong><\/p>\n<p>Conocer bien:<\/p>\n<ul>\n<li>Las aplicaciones reales del laboratorio<\/li>\n<li>Las especificaciones del equipo<\/li>\n<li>Cu\u00e1ndo es momento de actualizar o cambiar de modelo<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>7. No formar adecuadamente al personal<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>El \u00faltimo error&#8230; y uno de los m\u00e1s cr\u00edticos.<\/p>\n<p><strong>Qu\u00e9 ocurre<\/strong><\/p>\n<ul>\n<li>\u00abAprender por imitaci\u00f3n\u00bb<\/li>\n<li>Protocolos que se transmiten de persona a persona<\/li>\n<li>Malos h\u00e1bitos que se normalizan<\/li>\n<\/ul>\n<p><strong>La soluci\u00f3n<\/strong><\/p>\n<ul>\n<li>Formaci\u00f3n inicial y peri\u00f3dica<\/li>\n<li>Protocolos claros y accesibles<\/li>\n<li>Acompa\u00f1amiento t\u00e9cnico cuando surgen dudas<\/li>\n<\/ul>\n<p>Un equipo bien usado dura m\u00e1s, falla menos y da mejores resultados.<\/p>\n<ul>\n<li>Paradas inesperadas<\/li>\n<li>Costes de reparaci\u00f3n elevados<\/li>\n<\/ul>\n<p><strong>La clave<\/strong><\/p>\n<p>Conocer bien:<\/p>\n<ul>\n<li>Las aplicaciones reales del laboratorio<\/li>\n<li>Las especificaciones del equipo<\/li>\n<li>Cu\u00e1ndo es momento de actualizar o cambiar de modelo<\/li>\n<\/ul>\n<p>\n<\/div><div class=\"uncode-single-media  text-left\"><div class=\"single-wrapper\" style=\"max-width: 100%;\"><div class=\"tmb tmb-light  tmb-media-first tmb-media-last tmb-content-overlay tmb-no-bg\"><div class=\"t-inside\"><div class=\"t-entry-visual\"><div class=\"t-entry-visual-tc\"><div class=\"uncode-single-media-wrapper\"><img decoding=\"async\" class=\"wp-image-156859\" src=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/1736r_right_opened.jpg\" width=\"651\" height=\"1200\" alt=\"\" srcset=\"https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/1736r_right_opened.jpg 651w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/1736r_right_opened-163x300.jpg 163w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/1736r_right_opened-556x1024.jpg 556w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/1736r_right_opened-7x12.jpg 7w, https:\/\/www.controltecnica.com\/wp-content\/uploads\/2026\/03\/1736r_right_opened-350x645.jpg 350w\" sizes=\"(max-width: 651px) 100vw, 651px\" \/><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div><\/div><\/div><\/div><\/div><div class=\"vc_custom_heading_wrap\"><div class=\"heading-text el-text\" ><\/p>\n<h2>Conclusi\u00f3n: la centr\u00edfuga tambi\u00e9n merece atenci\u00f3n<\/h2>\n<p>\n<\/div><div class=\"clear\"><\/div><\/div><div class=\"uncode_text_column\" ><p>La centr\u00edfuga es uno de esos equipos que parecen sencillos, hasta que fallan.<\/p>\n<p>Prestar atenci\u00f3n a su uso correcto no solo mejora los resultados del laboratorio, sino que:<\/p>\n<ul>\n<li>Reduce costes<\/li>\n<li>Evita paradas inesperadas<\/li>\n<li>Aumenta la seguridad<\/li>\n<li>Garantiza la reproducibilidad de los ensayos<\/li>\n<\/ul>\n<p>En Controltecnica BIO no solo suministramos equipos: Te asesoramos, te acompa\u00f1amos y te ayudamos a sacarles el m\u00e1ximo partido.<\/p>\n<p>\u00bfTienes dudas sobre tu centr\u00edfuga actual o est\u00e1s valorando renovar el equipo?<\/p>\n<p>Escr\u00edbenos y lo vemos contigo, sin compromiso.<\/p>\n<p>\ud83d\udce7<a href=\"http:\/\/www.controltecnica.com\/bio\/contacto\" target=\"_blank\" rel=\"noopener\">www.controltecnica.com\/bio\/contacto<\/a><\/p>\n<\/div><\/div><\/div><\/div><\/div><\/div><script id=\"script-row-unique-0\" data-row=\"script-row-unique-0\" type=\"text\/javascript\" class=\"vc_controls\">UNCODE.initRow(document.getElementById(\"row-unique-0\"));<\/script><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"Las centr\u00edfugas est\u00e1n en casi todos los laboratorios. Se usan a diario, forma parte de la rutina&#8230; y precisamente por [...]","protected":false},"author":3,"featured_media":84211,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"iawp_total_views":80,"footnotes":""},"categories":[101,6],"tags":[158,159],"class_list":["post-156847","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-instrumentacion-cientifica-bio","category-servicio-tecnico-sat","tag-centrifuga-ideal","tag-centrifugas"],"_links":{"self":[{"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/posts\/156847","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/comments?post=156847"}],"version-history":[{"count":8,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/posts\/156847\/revisions"}],"predecessor-version":[{"id":156869,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/posts\/156847\/revisions\/156869"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/media\/84211"}],"wp:attachment":[{"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/media?parent=156847"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/categories?post=156847"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.controltecnica.com\/en\/wp-json\/wp\/v2\/tags?post=156847"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}